Haku

Assessment of downward draught in high-glazing facades in cold climates-Experimental and CFD study into draught control with a 21-type radiator

QR-koodi

Assessment of downward draught in high-glazing facades in cold climates-Experimental and CFD study into draught control with a 21-type radiator

This paper investigates the interaction of a radiator's thermal plume and downdraught of cold glazed surfaces. Draughts in working areas are one of the most common thermal comfort complaints in modern buildings. A typical solution for dealing with these draughts is positioning the heat emitters such as radiators or convectors under the windows. However, with thermally efficient envelopes, the internal loads compromise a relatively high fraction of the heating demand and the emitters are working under partial loads in modern buildings. This study comprises two parts: an experimental phase in the EN442 standardized test chamber with a 21-type radiator, and a CFD simulation phase, where the model is validated and applied under an expanded set of boundary conditions. The expanded simulation set results provide preliminary insight into sizing and design. More specifically, the thermal plume can be parametrised with a velocity and temperature value along with the room air and glazing temperatures for a broader analysis and assessment of the risk of draught.

Tallennettuna: